Properties of a commercial PTW-60019 synthetic diamond detector for the dosimetry of small radiotherapy beams JM Lárraga-Gutiérrez, P Ballesteros-Zebadúa, M Rodríguez-Ponce, ... Physics in Medicine & Biology 60 (2), 905, 2015 | 124 | 2015 |
Radiation transmission, leakage and beam penumbra measurements of a micro-multileaf collimator using GafChromic EBT film A García-Garduño, MA Celis, JM Lárraga-Gutiérrez, S Moreno-Jiménez, ... Journal of Applied Clinical Medical Physics 9 (3), 90-98, 2008 | 68 | 2008 |
Small photon beam measurements using radiochromic film and Monte Carlo simulations in a water phantom OA García-Garduño, JM Lárraga-Gutiérrez, M Rodríguez-Villafuerte, ... Radiotherapy and Oncology 96 (2), 250-253, 2010 | 63 | 2010 |
Corpus callosotomy using conformal stereotactic radiosurgery MA Celis, S Moreno-Jiménez, JM Lárraga-Gutiérrez, MA Alonso-Vanegas, ... Child's Nervous System 23, 917-920, 2007 | 37 | 2007 |
Investigation of EBT 3 radiochromic film's response to humidity EY León‐Marroquín, JM Lárraga‐Gutiérrez, JA Herrera‐González, ... Journal of applied clinical medical physics 19 (3), 283-290, 2018 | 29 | 2018 |
Evaluation of a LED-based flatbed document scanner for radiochromic film dosimetry in transmission mode JM Lárraga-Gutiérrez, OA García-Garduño, C Treviño-Palacios, ... Physica Medica 47, 86-91, 2018 | 28 | 2018 |
Evaluation of the Gafchromic® EBT2 film for the dosimetry of radiosurgical beams JM Lárraga‐Gutiérrez, D García‐Hernández, OA García‐Garduño, ... Medical physics 39 (10), 6111-6117, 2012 | 28 | 2012 |
Intracranial arteriovenous malformations treated with linear accelerator–based conformal radiosurgery: clinical outcome and prediction of obliteration S Moreno-Jiménez, MA Celis, JM Lárraga-Gutiérrez, ... Surgical neurology 67 (5), 487-491, 2007 | 26 | 2007 |
Effect of correction methods of radiochromic EBT2 films on the accuracy of IMRT QA OA García-Garduño, JM Lárraga-Gutiérrez, M Rodríguez-Villafuerte, ... Applied Radiation and Isotopes 107, 121-126, 2016 | 23 | 2016 |
Assessment of an image-guided neurosurgery system using a head phantom P Ballesteros-Zebadúa, OA García-Garduño, OO Galván de La Cruz, ... British journal of neurosurgery 30 (6), 606-610, 2016 | 21 | 2016 |
Experimental determination of field factors () for small radiotherapy beams using the daisy chain correction method JM Lárraga-Gutiérrez Physics in Medicine & Biology 60 (15), 5813, 2015 | 17 | 2015 |
Diffusion tensor imaging in radiosurgical callosotomy S Moreno-Jiménez, D San-Juan, JM Lárraga-Gutiérrez, MA Celis, ... Seizure 21 (6), 473-477, 2012 | 16 | 2012 |
Comparative analysis of several detectors for the measurement of radiation transmission and leakage from a multileaf collimator JM Lárraga-Gutiérrez, OOG de la Cruz, OA García-Garduño, ... Physica Medica 30 (3), 391-395, 2014 | 14 | 2014 |
Diagnostic approach in suspected recurrent primary brain tumors using 18FDG-PET/MRI, perfusion MRI, visual and quantitative analysis, and three dimensional stereotactic surface … G Estrada, L González-Maya, MA Celis-López, J Gavito, ... Revista Espanola de Medicina Nuclear 27 (5), 329-339, 2008 | 11 | 2008 |
Experimental determination of field factors (Ω Q clin, Q msr f clin, f msr) for small radiotherapy beams using the daisy chain correction method JM Lárraga-Gutiérrez Physics in Medicine and Biology 60 (15), 5813-5831, 2015 | 10 | 2015 |
Intracranial arteriovenous malformations treated with LINAC-based conformal radiosurgery: validation of the radiosurgery-based arteriovenous malformation score as a predictor … S Moreno-Jimenez, MA Celis, JM Larraga-Gutierrez, JJ Suarez-Campos, ... Neurological Research 29 (7), 712-716, 2007 | 10 | 2007 |
Calculation of beam quality correction factors for EBT3 radiochromic film JM Lárraga-Gutiérrez Physica Medica: European Journal of Medical Physics 30, e62, 2014 | 6 | 2014 |
Comparison of trigeminal neuralgia radiosurgery plans using two film detectors for the commissioning of small photon beams KP Esparza‐Moreno, OA Garcáa‐Garduño, P Ballesteros‐Zebadúa, ... Journal of Applied Clinical Medical Physics 14 (6), 18-26, 2013 | 6 | 2013 |
A novel stereotactic device for spinal irradiation in rats designed for a linear accelerator EE Galván, JM Lárraga-Gutiérrez, MA Celis, S Moreno-Jiménez, ... Stereotactic and Functional Neurosurgery 88 (2), 115-120, 2010 | 6 | 2010 |
Evaluation of Acuros® XB accuracy for static small fields dose calculations based on the IAEA/AAPM TRS-483 recommendation JM Lárraga-Gutiérrez, OA García-Garduño, JA Herrera-González, ... Physica Medica 89, 140-146, 2021 | 5 | 2021 |