フォロー
Jerdvisanop Chakarothai
タイトル
引用先
引用先
Exposure evaluation of an actual Wireless Power Transfer system for an electric vehicle with near-field measurement
J Chakarothai, K Wake, T Arima, S Watanabe, T Uno
IEEE Transactions on Microwave Theory and Techniques 66 (3), 1543-1552, 2017
512017
Derivation of Coupling Factors for Different Wireless Power Transfer Systems: Inter-and Intralaboratory Comparison
K Wake, I Laakso, A Hirata, J Chakarothai, T Onishi, S Watanabe, ...
IEEE Transactions on Electromagnetic Compatibility 59 (2), 677-685, 2017
352017
Novel FDTD scheme for analysis of frequency-dependent medium using fast inverse Laplace transform and Prony’s method
J Chakarothai
IEEE Transactions on Antennas and Propagation 67 (9), 6076-6089, 2018
292018
Dosimetry of a reverberation chamber for whole-body exposure of small animals
J Chakarothai, J Wang, O Fujiwara, K Wake, S Watanabe
IEEE Transactions on Microwave Theory and Techniques 61 (9), 3435-3445, 2013
292013
Error Analysis of a Near-Field Reconstruction Technique Based on Plane Wave Spectrum Expansion for Power Density Assessment Above 6 GHz
K Sasaki, K Li, J Chakarothai, T Iyama, T Onishi, S Watanabe
IEEE Access 7, 11591-11598, 2019
272019
A hybrid MoM/FDTD method for dosimetry of small animal in reverberation chamber
J Chakarothai, J Wang, O Fujiwara, K Wake, S Watanabe
IEEE Transactions on Electromagnetic Compatibility 56 (3), 549-558, 2014
202014
Relationship of External Field Strength With Local and Whole-Body Averaged Specific Absorption Rates in Anatomical Human Models
K Taguchi, I Laakso, K Aga, A Hirata, Y Diao, J Chakarothai, T Kashiwa
IEEE Access 6, 70186-70196, 2018
172018
Convergence of a Single-Frequency FDTD Solution in Numerical Dosimetry
J Chakarothai, K Wake, S Watanabe
IEEE Transactions on Microwave Theory and Techniques 64 (3), 707-714, 2016
172016
Numerical Dosimetry of Electromagnetic Pulse Exposures Using FDTD Method
J Chakarothai, S Watanabe, K Wake
IEEE Transactions on Antennas and Propagation 66 (10), 5397-5408, 2018
152018
Quantification and Verification of Whole-Body-Average SARs in Small Animals Exposed to Electromagnetic Fields inside Reverberation Chamber
SHI Jingjing, J Chakarothai, W Jianqing, W Kanako, S Watanabe, ...
IEICE Transactions on Communications 97 (10), 2184-2191, 2014
132014
Scalable GPU-parallelized FDTD method for analysis of large-scale electromagnetic dosimetry problems
J Chakarothai, K Wake, S Watanabe
The Applied Computational Electromagnetics Society Journal (ACES), 661-668, 2016
122016
Evaluation of EM absorption characteristics in realistic adult and child models in vicinity of wireless power transfer systems
J Chakarothai, W Kanako, S Watanabe
2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC), 448-451, 2015
122015
Probe Calibration in Lossy Liquid Using Small Dipole Antennas for Megahertz-Band Specific Absorption Rate Measurements
N Ishii, J Chakarothai, K Wake, S Watanabe
IEEE Transactions on Instrumentation and Measurement 69 (6), 3078-3088, 2019
82019
Dosimetry and verification for 6-GHz whole-body non-constraint exposure of rats using reverberation chamber
J Shi, J Chakarothai, J Wang, K Wake, S Watanabe, O Fujiwara
IEICE Transactions on Communications 98 (7), 1164-1172, 2015
82015
Numerical techniques for SAR assessment of small animals in reverberation chamber
J Chakarothai, J Shi, J Wang, O Fujiwara, K Wake, S Watanabe
IEEE Electromagnetic Compatibility Magazine 4 (1), 57-66, 2015
82015
Estimation of current distribution by near-field measurement
Q Chen, J Chakarothai, K Sawaya
2009 5th Asia-Pacific Conference on Environmental Electromagnetics, 416-419, 2009
82009
SAR assessment of a human body exposed to electromagnetic fields from a wireless power transfer system in 10 MHz band
J Chakarothai, K Wake, S Watanabe
2014 XXXIth URSI General Assembly and Scientific Symposium (URSI GASS), 1-4, 2014
72014
Improvement of SAR Accuracy by Combining Two SAR Quantification Methods for Small Animals in Reverberation Chamber Above 10 GHz
J Shi, J Chakarothai, J Wang, O Fujiwara, K Wake, S Watanabe
IEEE Access 8, 138170-138178, 2020
52020
A new extrapolation expression for exposure evaluation inside a human-equivalent liquid phantom in the vicinity of wireless power transfer systems
S Shimoyama, J Chakarothai, K Wake, T Arima, S Watanabe, T Uno
Annals of Telecommunications 74, 53-65, 2019
42019
Analysis of millimeter-wave exposure on rabbit eye using a hybrid PMCHWT-MoM-FDTD method
J Chakarothai, Y Suzuki, M Taki, K Wake, K Sasaki, S Watanabe, ...
2013 Proceedings of the International Symposium on Antennas & Propagation 1 …, 2013
42013
現在システムで処理を実行できません。しばらくしてからもう一度お試しください。
論文 1–20