フォロー
Dr. K. V. Gobi
タイトル
引用先
引用先
Recent advancements in surface plasmon resonance immunosensors for detection of small molecules of biomedical, food and environmental interest
DR Shankaran, KV Gobi, N Miura
Sensors and Actuators B: Chemical 121 (1), 158-177, 2007
7672007
An electrochemical aptasensor based on functionalized graphene oxide assisted electrocatalytic signal amplification of methylene blue for aflatoxin B1 detection
KY Goud, A Hayat, G Catanante, M Satyanarayana, KV Gobi, JL Marty
Electrochimica Acta 244, 96-103, 2017
204*2017
Progress on nanostructured electrochemical sensors and their recognition elements for detection of mycotoxins: A review
KY Goud, SK Kailasa, V Kumar, YF Tsang, KV Gobi, KH Kim
Biosensors and Bioelectronics 121, 205-222, 2018
1802018
Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin
KV Gobi, H Iwasaka, N Miura
Biosensors and Bioelectronics 22 (7), 1382-1389, 2007
1672007
Surface plasmon resonance immunosensor for highly sensitive detection of 2, 4, 6-trinitrotoluene
DR Shankaran, KV Gobi, T Sakai, K Matsumoto, K Toko, N Miura
Biosensors and Bioelectronics 20 (9), 1750-1756, 2005
1322005
Disposable and portable electrochemical aptasensor for label free detection of aflatoxin B1 in alcoholic beverages
KY Goud, G Catanante, A Hayat, M Satyanarayana, KV Gobi, JL Marty
Sensors and Actuators B: Chemical 235, 466-473, 2016
1282016
Efficient mediatorless superoxide sensors using cytochrome c-modified electrodes: surface nano-organization for selectivity and controlled peroxidase activity
KV Gobi, F Mizutani
Journal of Electroanalytical Chemistry 484 (2), 172-181, 2000
1212000
A review on recent developments in optical and electrochemical aptamer-based assays for mycotoxins using advanced nanomaterials
KY Goud, KK Reddy, M Satyanarayana, S Kummari, KV Gobi
Microchimica Acta 187 (1), 1-32, 2020
1162020
Highly sensitive and selective surface plasmon resonance sensor for detection of sub-ppb levels of benzo [a] pyrene by indirect competitive immunoreaction method
N Miura, M Sasaki, KV Gobi, C Kataoka, Y Shoyama
Biosensors and Bioelectronics 18 (7), 953-959, 2003
1162003
Novel miniature SPR immunosensor equipped with all-in-one multi-microchannel sensor chip for detecting low-molecular-weight analytes
SJ Kim, KV Gobi, H Iwasaka, H Tanaka, N Miura
Biosensors and Bioelectronics 23 (5), 701-707, 2007
1142007
Disposable and portable electrochemical aptasensor for label free detection of aflatoxin B1 in alcoholic beverages
KY Goud, G Catanante, A Hayat, M Satyanarayana, KV Gobi, JL Marty
Sensors and Actuators B: Chemical 235, 466-473, 2016
1102016
Layer-by-layer construction of an active multilayer enzyme electrode applicable for direct amperometric determination of cholesterol
K Vengatajalabathy Gobi, F Mizutani
Sensors and Actuators B: Chemical 80 (3), 272-277, 2001
942001
Highly sensitive regenerable immunosensor for label-free detection of 2, 4-dichlorophenoxyacetic acid at ppb levels by using surface plasmon resonance imaging
KV Gobi, H Tanaka, Y Shoyama, N Miura
Sensors and Actuators B: Chemical 111, 562-571, 2005
872005
Surface plasmon resonance biosensor for dopamine using D3 dopamine receptor as a biorecognition molecule
S Kumbhat, DR Shankaran, SJ Kim, KV Gobi, V Joshi, N Miura
Biosensors and Bioelectronics 23 (3), 421-427, 2007
852007
Fabrication of a novel immunosensor using functionalized self-assembled monolayer for trace level detection of TNT by surface plasmon resonance
T Kawaguchi, DR Shankaran, SJ Kim, KV Gobi, K Matsumoto, K Toko, ...
Talanta 72 (2), 554-560, 2007
852007
Highly sensitive surface plasmon resonance immunosensor for parts-per-trillion level detection of 2, 4, 6-trinitrophenol
DR Shankaran, KV Gobi, K Matsumoto, T Imato, K Toko, N Miura
Sensors and Actuators B: Chemical 100 (3), 450-454, 2004
812004
Electrochemical diagnostics of infectious viral diseases: Trends and challenges
KY Goud, KK Reddy, A Khorshed, VS Kumar, RK Mishra, M Oraby, ...
Biosensors and Bioelectronics 180, 113112, 2021
782021
Compact surface plasmon resonance (SPR) immunosensor using multichannel for simultaneous detection of small molecule compounds
H Kawazumi, KV Gobi, K Ogino, H Maeda, N Miura
Sensors and Actuators B: Chemical 108 (1-2), 791-796, 2005
772005
Continuous flow immunosensor for highly selective and real-time detection of sub-ppb levels of 2-hydroxybiphenyl by using surface plasmon resonance imaging
KV Gobi, H Tanaka, Y Shoyama, N Miura
Biosensors and Bioelectronics 20 (2), 350-357, 2004
732004
Miniaturized portable surface plasmon resonance immunosensor applicable for on-site detection of low-molecular-weight analytes
SJ Kim, KV Gobi, R Harada, DR Shankaran, N Miura
Sensors and Actuators B: Chemical 115 (1), 349-356, 2006
712006
現在システムで処理を実行できません。しばらくしてからもう一度お試しください。
論文 1–20