Robust multiframe super-resolution employing iteratively re-weighted minimization T Köhler, X Huang, F Schebesch, A Aichert, A Maier, J Hornegger IEEE Transactions on Computational Imaging 2 (1), 42-58, 2016 | 106 | 2016 |
Epipolar consistency in transmission imaging A Aichert, M Berger, J Wang, N Maass, A Doerfler, J Hornegger, AK Maier IEEE transactions on medical imaging 34 (11), 2205-2219, 2015 | 93 | 2015 |
Marker‐free motion correction in weight‐bearing cone‐beam CT of the knee joint M Berger, K Müller, A Aichert, M Unberath, J Thies, JH Choi, R Fahrig, ... Medical physics 43 (3), 1235-1248, 2016 | 75 | 2016 |
Real-time volume rendering for high quality visualization in augmented reality O Kutter, A Aichert, C Bichlmeier, J Traub, SM Heining, B Ockert, E Euler, ... International Workshop on Augmented environments for Medical Imaging …, 2008 | 61 | 2008 |
On the energetics of conformational switching of molecules at and close to room temperature S Ditze, M Stark, F Buchner, A Aichert, N Jux, N Luckas, A Görling, ... Journal of the American Chemical Society 136 (4), 1609-1616, 2014 | 47 | 2014 |
The effect of out-of-focus blur on visual discomfort when using stereo displays T Blum, M Wieczorek, A Aichert, R Tibrewal, N Navab 2010 IEEE International Symposium on Mixed and Augmented Reality, 13-17, 2010 | 47 | 2010 |
Motion compensation for cone-beam CT using Fourier consistency conditions M Berger, Y Xia, W Aichinger, K Mentl, M Unberath, A Aichert, C Riess, ... Physics in Medicine & Biology 62 (17), 7181, 2017 | 36 | 2017 |
A realistic digital phantom for perfusion C-arm CT based on MRI data A Aichert, MT Manhart, BK Navalpakkam, R Grimm, J Hutter, A Maier, ... 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS …, 2013 | 36 | 2013 |
Feature extraction techniques A Aichert Camp medical seminar ws0708, 1-8, 2008 | 35 | 2008 |
Image-based tracking of the teeth for orthodontic augmented reality A Aichert, W Wein, A Ladikos, T Reichl, N Navab International conference on medical image computing and computer-assisted …, 2012 | 31 | 2012 |
GPU-accelerated rendering for medical augmented reality in minimally-invasive procedures. M Wieczorek, A Aichert, O Kutter, C Bichlmeier, J Landes, SM Heining, ... Bildverarbeitung für die Medizin 574, 102-106, 2010 | 31 | 2010 |
Consistency‐based respiratory motion estimation in rotational angiography M Unberath, A Aichert, S Achenbach, A Maier Medical physics 44 (9), e113-e124, 2017 | 30 | 2017 |
Empirical Scatter Correction using the Epipolar Consistency Condition M Hoffmann, T Würfl, N Maaß, F Dennerlein, A Aichert, AK Maier The Fifth International Conference on Image Formation in X-Ray Computed …, 2018 | 25 | 2018 |
Geometrical jitter correction in computed tomography N Maass, F Dennerlein, A Aichert, A Maier Proceedings of the third international conference on image formation in X …, 2014 | 25 | 2014 |
Automatic non-linear mapping of pre-procedure CT volumes to 3D ultrasound W Wein, O Kutter, A Aichert, D Zikic, A Kamen, N Navab 2010 IEEE International Symposium on Biomedical Imaging: From Nano to Macro …, 2010 | 23 | 2010 |
An improved extrapolation scheme for truncated CT data using 2D Fourier-based Helgason-Ludwig consistency conditions Y Xia, M Berger, S Bauer, S Hu, A Aichert, A Maier International journal of biomedical imaging 2017, 2017 | 21 | 2017 |
Virtual Single-frame Subtraction Imaging M Unberath, A Aichert, S Achenbach, A Maier 4th International Conference on Image Formation in X-Ray Computed Tomography …, 2016 | 20 | 2016 |
Denoising and artefact reduction in dynamic flat detector CT perfusion imaging using high speed acquisition: first experimental and clinical results MT Manhart, A Aichert, T Struffert, Y Deuerling-Zheng, M Kowarschik, ... Physics in Medicine & Biology 59 (16), 4505, 2014 | 20 | 2014 |
Interactive 3D visualization of a single-view X-Ray image M Wieczorek, A Aichert, P Fallavollita, O Kutter, A Ahmadi, L Wang, ... Medical Image Computing and Computer-Assisted Intervention–MICCAI 2011: 14th …, 2011 | 20 | 2011 |
Calibration‐free beam hardening reduction in x‐ray CBCT using the epipolar consistency condition and physical constraints T Würfl, M Hoffmann, A Aichert, AK Maier, N Maaß, F Dennerlein Medical physics 46 (12), e810-e822, 2019 | 15 | 2019 |