フォロー
Ryoji Kurita
タイトル
引用先
引用先
On-chip enzyme immunoassay of a cardiac marker using a microfluidic device combined with a portable surface plasmon resonance system
R Kurita, Y Yokota, Y Sato, F Mizutani, O Niwa
Analytical chemistry 78 (15), 5525-5531, 2006
2022006
Electrochemical performance of angstrom level flat sputtered carbon film consisting of sp2 and sp3 mixed bonds
O Niwa, J Jia, Y Sato, D Kato, R Kurita, K Maruyama, K Suzuki, S Hirono
Journal of the American Chemical Society 128 (22), 7144-7145, 2006
2022006
A nanocarbon film electrode as a platform for exploring DNA methylation
D Kato, N Sekioka, A Ueda, R Kurita, S Hirono, K Suzuki, O Niwa
Journal of the American Chemical Society 130 (12), 3716-3717, 2008
1852008
Structure and electrochemical properties of carbon films prepared by a electron cyclotron resonance sputtering method
J Jia, D Kato, R Kurita, Y Sato, K Maruyama, K Suzuki, S Hirono, T Ando, ...
Analytical chemistry 79 (1), 98-105, 2007
1172007
Microfluidic device integrated with pre-reactor and dual enzyme-modified microelectrodes for monitoring in vivo glucose and lactate
R Kurita, K Hayashi, X Fan, K Yamamoto, T Kato, O Niwa
Sensors and Actuators B: Chemical 87 (2), 296-303, 2002
1052002
Accurate and reproducible detection of proteins in water using an extended-gate type organic transistor biosensor
T Minamiki, T Minami, R Kurita, O Niwa, S Wakida, K Fukuda, D Kumaki, ...
Applied Physics Letters 104 (24), 2014
1042014
Redox alters yellow dragonflies into red
R Futahashi, R Kurita, H Mano, T Fukatsu
Proceedings of the National Academy of Sciences 109 (31), 12626-12631, 2012
952012
Development of electrogenerated chemiluminescence-based enzyme linked immunosorbent assay for sub-pM detection
R Kurita, K Arai, K Nakamoto, D Kato, O Niwa
Analytical chemistry 82 (5), 1692-1697, 2010
932010
Nanohybrid carbon film for electrochemical detection of SNPs without hybridization or labeling
D Kato, N Sekioka, A Ueda, R Kurita, S Hirono, K Suzuki, O Niwa
Angewandte Chemie-International Edition 47 (35), 6681-6684, 2008
932008
Selective nitrate detection by an enzymatic sensor based on an extended-gate type organic field-effect transistor
T Minami, Y Sasaki, T Minamiki, S Wakida, R Kurita, O Niwa, S Tokito
Biosensors and Bioelectronics 81, 87-91, 2016
872016
Small-volume on-line sensor for continuous measurement of γ-aminobutyric acid
O Niwa, R Kurita, T Horiuchi, K Torimitsu
Analytical chemistry 70 (1), 89-93, 1998
861998
Determination of DNA methylation using electrochemiluminescence with surface accumulable coreactant
R Kurita, K Arai, K Nakamoto, D Kato, O Niwa
Analytical chemistry 84 (4), 1799-1803, 2012
832012
Development of a mass-producible on-chip plasmonic nanohole array biosensor
K Nakamoto, R Kurita, O Niwa, T Fujii, M Nishida
Nanoscale 3 (12), 5067-5075, 2011
742011
On-line electrochemical sensor for selective continuous measurement of acetylcholine in cultured brain tissue
O Niwa, T Horiuchi, R Kurita, K Torimitsu
Analytical chemistry 70 (6), 1126-1132, 1998
711998
Efficient direct electron transfer with enzyme on a nanostructured carbon film fabricated with a maskless top-down UV/ozone process
A Ueda, D Kato, R Kurita, T Kamata, H Inokuchi, S Umemura, S Hirono, ...
Journal of the American Chemical Society 133 (13), 4840-4846, 2011
672011
A label-free immunosensor for IgG based on an extended-gate type organic field effect transistor
T Minamiki, T Minami, R Kurita, O Niwa, S Wakida, K Fukuda, D Kumaki, ...
Materials 7 (9), 6843-6852, 2014
652014
Controllable electrode activities of nano-carbon films while maintaining surface flatness by electrochemical pretreatment
N Sekioka, D Kato, A Ueda, T Kamata, R Kurita, S Umemura, S Hirono, ...
Carbon 46 (14), 1918-1926, 2008
652008
Miniaturized one-chip electrochemical sensing device integrated with a dialysis membrane and double thin-layer flow channels for measuring blood samples
R Kurita, N Yabumoto, O Niwa
Biosensors and Bioelectronics 21 (8), 1649-1653, 2006
602006
Reductive H2O2 Detection at Nanoparticle Iridium/Carbon Film Electrode and Its Application as L‐Glutamate Enzyme Sensor
T You, O Niwa, R Kurita, Y Iwasaki, K Hayashi, K Suzuki, S Hirono
Electroanalysis: An International Journal Devoted to Fundamental and …, 2004
602004
Carbon film-based interdigitated array microelectrode used in capillary electrophoresis with electrochemical detection
Z Liu, O Niwa, R Kurita, T Horiuchi
Analytical chemistry 72 (6), 1315-1321, 2000
602000
現在システムで処理を実行できません。しばらくしてからもう一度お試しください。
論文 1–20