Simultaneous determination of nitrate and nitrite ions in seawater by capillary zone electrophoresis using artificial seawater as the carrier solution K Fukushi, K Tada, S Takeda, S Wakida, M Yamane, K Higashi, K Hiiro Journal of Chromatography A 838 (1-2), 303-311, 1999 | 3398 | 1999 |
Quartz crystal microbalance immunosensors for environmental monitoring S Kurosawa, JW Park, H Aizawa, SI Wakida, H Tao, K Ishihara Biosensors and Bioelectronics 22 (4), 473-481, 2006 | 202 | 2006 |
Simultaneous determination of nitrite, nitrate, thiocyanate and uric acid in human saliva by capillary zone electrophoresis and its application to the study of daily variations Y Tanaka, N Naruishi, H Fukuya, J Sakata, K Saito, S Wakida Journal of Chromatography A 1051 (1-2), 193-197, 2004 | 119 | 2004 |
Accurate and reproducible detection of proteins in water using an extended-gate type organic transistor biosensor T Minamiki, T Minami, R Kurita, O Niwa, S Wakida, K Fukuda, D Kumaki, ... Applied Physics Letters 104 (24), 2014 | 103 | 2014 |
Photouncaging Nanoparticles for MRI and Fluorescence Imaging in Vitro and in Vivo ES Shibu, K Ono, S Sugino, A Nishioka, A Yasuda, Y Shigeri, S Wakida, ... Acs Nano 7 (11), 9851-9859, 2013 | 91 | 2013 |
Application of capillary electrophoresis to the analysis of inorganic ions in environmental samples K Fukushi, S Takeda, K Chayama, SI Wakida Journal of Chromatography A 834 (1-2), 349-362, 1999 | 91 | 1999 |
Simultaneous determination of nitrate and nitrite in biological fluids by capillary electrophoresis and preliminary study on their determination by microchip capillary … T Miyado, Y Tanaka, H Nagai, S Takeda, K Saito, K Fukushi, Y Yoshida, ... Journal of Chromatography A 1051 (1-2), 185-191, 2004 | 90 | 2004 |
Selective nitrate detection by an enzymatic sensor based on an extended-gate type organic field-effect transistor T Minami, Y Sasaki, T Minamiki, S Wakida, R Kurita, O Niwa, S Tokito Biosensors and Bioelectronics 81, 87-91, 2016 | 87 | 2016 |
Migration behavior of phthalate esters in micellar electrokinetic chromatography with or without added methanol S Takeda, S Wakida, M Yamane, A Kawahara, K Higashi Analytical Chemistry 65 (18), 2489-2492, 1993 | 80 | 1993 |
Simultaneous determination of iodide and iodate in seawater by transient isotachophoresis–capillary zone electrophoresis with artificial seawater as the background electrolyte K Yokota, K Fukushi, S Takeda, SI Wakida Journal of Chromatography A 1035 (1), 145-150, 2004 | 78 | 2004 |
ストレスと疲労のバイオマーカー 田中喜秀, 脇田慎一 日本薬理学雑誌 137 (4), 185-188, 2011 | 72 | 2011 |
Simultaneous separation and on-line concentration of amitrole and benzimidazole pesticides by capillary electrophoresis with a volatile migration buffer applicable to mass … S Takeda, K Fukushi, K Chayama, Y Nakayama, Y Tanaka, S Wakida Journal of chromatography A 1051 (1-2), 297-301, 2004 | 70 | 2004 |
Single-molecular surface-enhanced resonance Raman scattering as a quantitative probe of local electromagnetic field: The case of strong coupling between plasmonic and excitonic … T Itoh, YS Yamamoto, H Tamaru, V Biju, S Wakida, Y Ozaki Physical Review B 89 (19), 195436, 2014 | 69 | 2014 |
A label-free immunosensor for IgG based on an extended-gate type organic field effect transistor T Minamiki, T Minami, R Kurita, O Niwa, S Wakida, K Fukuda, D Kumaki, ... Materials 7 (9), 6843-6852, 2014 | 65 | 2014 |
Comparison of stabilizing effect of stabilizers for immobilized antibodies on QCM immunosensors JW Park, S Kurosawa, H Aizawa, S Wakida, S Yamada, K Ishihara Sensors and Actuators B: Chemical 91 (1-3), 158-162, 2003 | 55 | 2003 |
Determination of bromide ions in seawater by capillary zone electrophoresis using diluted artificial seawater as the buffer solution K Fukushi, K Watanabe, S Takeda, SI Wakida, M Yamane, K Higashi, ... Journal of Chromatography A 802 (1), 211-217, 1998 | 49 | 1998 |
Phosphate ion-sensitive coated-wire/field-effect transistor electrode based on cobalt phthalocyanine with poly (vinyl chloride) as the membrane matrix J Liu, Y Masuda, E Sekido, SI Wakida, K Hiiro Analytica chimica acta 224, 145-151, 1989 | 49 | 1989 |
Separation and on-line concentration of bisphenol A and alkylphenols by micellar electrokinetic chromatography with cationic surfactant S Takeda, A Omura, K Chayama, H Tsuji, K Fukushi, M Yamane, ... Journal of Chromatography A 979 (1-2), 425-429, 2002 | 46 | 2002 |
Determination of nitrite and nitrate in a proposed certified reference material for nutrients in seawater by capillary zone electrophoresis with artificial seawater as the … K Fukushi, T Miyado, N Ishio, H Nishio, K Saito, S Takeda, S Wakida Electrophoresis 23 (12), 1928-1934, 2002 | 45 | 2002 |
Auger Ionization Beats Photo‐Oxidation of Semiconductor Quantum Dots: Extended Stability of Single‐Molecule Photoluminescence S Yamashita, M Hamada, S Nakanishi, H Saito, Y Nosaka, S Wakida, ... Angewandte Chemie International Edition 54 (13), 3892-3896, 2015 | 43 | 2015 |