Classifying vortex wakes using neural networks B Colvert, M Alsalman, E Kanso Bioinspiration & biomimetics 13 (2), 025003, 2018 | 113 | 2018 |
Training bioinspired sensors to classify flows M Alsalman, B Colvert, E Kanso Bioinspiration & biomimetics 14 (1), 016009, 2018 | 38 | 2018 |
Fishlike rheotaxis B Colvert, E Kanso Journal of Fluid Mechanics 793, 656-666, 2016 | 26 | 2016 |
Local flow characterization using bioinspired sensory information B Colvert, K Chen, E Kanso Journal of Fluid Mechanics 818, 366-381, 2017 | 12 | 2017 |
Octree representation improves data fidelity of cardiac CT images and convolutional neural network semantic segmentation of left atrial and ventricular chambers K Gupta, N Sekhar, DM Vigneault, AR Scott, B Colvert, A Craine, ... Radiology: Artificial Intelligence 3 (6), e210036, 2021 | 9 | 2021 |
Bioinspired sensory systems for shear flow detection B Colvert, KK Chen, E Kanso Journal of Nonlinear Science 27, 1183-1192, 2017 | 9 | 2017 |
Regional left ventricular endocardial strains estimated from low‐dose 4DCT: Comparison with cardiac magnetic resonance feature tracking A Manohar, GM Colvert, JE Ortuño, Z Chen, J Yang, BT Colvert, ... Medical physics 49 (9), 5841-5854, 2022 | 6 | 2022 |
Neural computed tomography K Gupta, B Colvert, F Contijoch arXiv preprint arXiv:2201.06574, 2022 | 6 | 2022 |
How can a source be located by responding to local information in its hydrodynamic trail? B Colvert, G Liu, H Dong, E Kanso 2017 IEEE 56th Annual Conference on Decision and Control (CDC), 2756-2761, 2017 | 6 | 2017 |
Flowtaxis in the wakes of oscillating airfoils B Colvert, G Liu, H Dong, E Kanso Theoretical and Computational Fluid Dynamics 34 (4), 545-556, 2020 | 4 | 2020 |
DiFiR‐CT: Distance field representation to resolve motion artifacts in computed tomography K Gupta, B Colvert, Z Chen, F Contijoch Medical physics 50 (3), 1349-1366, 2023 | 3 | 2023 |
Evaluating evasion strategies in zebrafish larvae Y Jiao, B Colvert, Y Man, MJ McHenry, E Kanso Proceedings of the National Academy of Sciences 120 (7), e2218909120, 2023 | 3 | 2023 |
Novel measurement of LV twist using 4DCT: quantifying accuracy as a function of image noise GM Colvert, A Manohar, B Colvert, A Schluchter, F Contijoch, E McVeigh Medical Imaging 2019: Biomedical Applications in Molecular, Structural, and …, 2019 | 3 | 2019 |
Heart‐centered positioning and tailored beam‐shaping filtration for reduced radiation dose in coronary artery calcium imaging: A Multi‐Ethnic Study of Atherosclerosis (MESA) Study B Colvert, M Rigolli, A Craine, M Criqui, F Contijoch Medical physics 48 (9), 4966-4977, 2021 | 2 | 2021 |
Short-scan Ct Paired With Beam Tailoring Minimizes Patient Dose In Radiosensitive Tissues. A Craine, B Colvert, F Contijoch Journal of Cardiovascular Computed Tomography 14 (3), S70, 2020 | 1 | 2020 |
Cardiacquire beam-shaping filter enables significant radiation dose reduction: patient-and organ-specific results B Colvert, A Craine, F Contijoch Journal of Cardiovascular Computed Tomography 14 (3), S70-S71, 2020 | 1 | 2020 |
A local sensory and control strategy for following hydrodynamic signals B Colvert, E Kanso arXiv preprint arXiv:1804.02442, 2018 | 1 | 2018 |
Dose reduction for cardiac computed tomography F Contijoch, B Colvert, E McVeigh US Patent 11,986,337, 2024 | | 2024 |
Wake Tracking by Copepods: importance of chemical and fluid mechanical cues J Yen, B Colvert, M Alsalman, Y Huang, E Kanso Ocean Sciences Meeting 2020, 2020 | | 2020 |
Zebrafish larvae evade by swimming orthogonally to predators Y Jiao, B Colvert, Y Man, M McHenry, E Kanso APS Division of Fluid Dynamics Meeting Abstracts, X01. 003, 2020 | | 2020 |