Jonathan Newell
Jonathan Newell
Professor of Biomedical Engineering, Rensselaer Polytechnic Institute
Verified email at rpi.edu
Title
Cited by
Cited by
Year
Electrical impedance tomography
M Cheney, D Isaacson, JC Newell
SIAM review 41 (1), 85-101, 1999
13361999
NOSER: An algorithm for solving the inverse conductivity problem
M Cheney, D Isaacson, JC Newell, S Simske, J Goble
International Journal of Imaging systems and technology 2 (2), 66-75, 1990
6911990
Electrode models for electric current computed tomography
KS Cheng, D Isaacson, JC Newell, DG Gisser
IEEE Transactions on Biomedical Engineering 36 (9), 918-924, 1989
6301989
Bi-level charge pulse apparatus to facilitate nerve location during peripheral nerve block procedures
RL Griffith, RJ Strowe, JC Newell, PM Edic, RF Messina, FC Houghton
US Patent 5,853,373, 1998
4441998
Modeling and analysis of dynamic systems
CM Close, DK Frederick, JC Newell
John Wiley & Sons, 2001
4042001
ACT3: a high-speed, high-precision electrical impedance tomograph
RD Cook, GJ Saulnier, DG Gisser, JC Goble, JC Newell, D Isaacson
IEEE Transactions on Biomedical Engineering 41 (8), 713-722, 1994
2821994
Bi-level charge pulse apparatus to facilitate nerve location during peripheral nerve block procedures
RL Griffith, RJ Strowe, JC Newell, PM Edic, RF Messina, FC Houghton
US Patent 6,325,764, 2001
2222001
Current source design for electrical impedance tomography
AS Ross, GJ Saulnier, JC Newell, D Isaacson
Physiological measurement 24 (2), 509, 2003
2142003
Electrical impedance tomography
GJ Saulnier, RS Blue, JC Newell, D Isaacson, PM Edic
IEEE Signal Processing Magazine 18 (6), 31-43, 2001
1952001
Regression of calculated variables in the presence of shared measurement error
HH Stratton, PJ Feustel, JC Newell
Journal of Applied Physiology 62 (5), 2083-2093, 1987
1941987
Electric current computed tomography and eigenvalues
DG Gisser, D Isaacson, JC Newell
SIAM Journal on Applied Mathematics 50 (6), 1623-1634, 1990
1821990
An electric current tomograph
JC Newell, DG Gisser, D Isaacson
IEEE Transactions on Biomedical Engineering 35 (10), 828-833, 1988
1791988
Reconstructions of chest phantoms by the D-bar method for electrical impedance tomography
D Isaacson, JL Mueller, JC Newell, S Siltanen
IEEE Transactions on medical imaging 23 (7), 821-828, 2004
1762004
A reconstruction algorithm for electrical impedance tomography data collected on rectangular electrode arrays
JL Mueller, D Isaacson, JC Newell
IEEE Transactions on Biomedical Engineering 46 (11), 1379-1386, 1999
1721999
Current topics in impedance imaging
DG Gisser, D Isaacson, JC Newell
Clinical Physics and Physiological Measurement 8 (4A), 39, 1987
1701987
Influence of hematocrit on cardiopulmonary function after acute hemorrhage.
JB Fortune, PJ Feustel, J Saifi, HH Stratton, JC Newell, DM Shah
The Journal of trauma 27 (3), 243-249, 1987
1381987
Indocyanine green: Its use as an early indicator of hepatic dysfunction following injury in man
ME Gottlieb, HH Stratton, JC Newell, DM Shah
Archives of surgery 119 (3), 264-268, 1984
1251984
Failure of red blood cell transfusion to increase oxygen transport or mixed venous PO2 in injured patients.
DM Shah, ME Gottlieb, RL Rahm, HH Stratton, PS Barie, WH Paloski, ...
The Journal of trauma 22 (9), 741-746, 1982
1211982
A real-time electrical impedance tomograph
PM Edic, GJ Saulnier, JC Newell, D Isaacson
IEEE Transactions on Biomedical Engineering 42 (9), 849-859, 1995
1191995
Imaging cardiac activity by the D-bar method for electrical impedance tomography
D Isaacson, JL Mueller, JC Newell, S Siltanen
Physiological Measurement 27 (5), S43, 2006
1112006
The system can't perform the operation now. Try again later.
Articles 1–20